BNRLJ - 369C0910 DEVTHANE 369 CLEAR CONVERTER

  • MSDS: BNRLJ
  • Manufacturer: DEVOE COATINGS COMPANY
  • Product Name: 369C0910 DEVTHANE 369 CLEAR CONVERTER
  • National Stock Number: 8010-01-306-0742
Product Identification

Product ID:369C0910 DEVTHANE 369 CLEAR CONVERTER
MSDS Date:10/27/1990
FSC:8010
NIIN:01-306-0742
Kit Part:Y
MSDS Number: BNRLJ

Responsible Party
DEVOE COATINGS COMPANY
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 302-897-9861

Cage: DO196

Contractor
DEVOE COATINGS COMPANY
7600 LOUISVILLE, KY 40207 US

Telephone: 502-897-9861, CHEMTREC 800-424-9300

Cage: DO196

Ingredients

13.

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 15%

OSHA PEL 150 PPM;200 PPM STEL

ACGIH TLV: 150 PPM;200 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOCYANIC ACID, HEXAMETHYLENE ESTER, POLYMERS; (POLYMERIC

CAS: 28182-81-2

RTECS: NQ9170000

Fraction By Weight: 75%

ACGIH TLV: 0.005 PPM (MFR)


(ORAL,RAT)>5 GM/KG. (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 15%

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


DECOMPOSITION PRODUCTS MAY CAUSE HEALTH HAZARD.

RTECS: 9999999ZZ


CLOSED CONTAINER UNTIL PROPERLY DISPOSED OF.

RTECS: 9999999ZZ


BUILD-UP OF VAPORS BY MAINTAINING CONTINUOUS

RTECS: 9999999ZZ


DO NOT TRANSFER CONTENTS TO BOTTLES/OTHER UNLABELLED

RTECS: 9999999ZZ


2-COMPONENT PROD, MIXT OF BASE & CONVERTER PORTIONS

RTECS: 9999999ZZ


MATERIAL COATED W/THIS PRODUCT.

RTECS: 9999999ZZ


HLTH STANDARDS IN MIXING, APPLICATION & CURING AREAS &

RTECS: 9999999ZZ


PRODS DURING WELDING & FLAME CUTTING ON SURFS COATED

RTECS: 9999999ZZ


BUILD-UP BY REMOVING HEAVY SOLVENT VAPORS FROM LOWER

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:IRRIT OF RESP TRACT; HDCH,
NAUSEA, DIZZ, WEAKNESS & FATIGUE. EXTREME EXPOS CAN RESULT IN UNCON
& EVEN RESP ARREST. MAY CAUSE ALLERGIC RXN. OVEREXP MAY CAUSE PERM
LUNG DMG. SKIN:CAUSES IRRI T. MAY BE HARMFUL IF ABSORBED THRU SKIN.
EYE:CAUSES IRRIT. INGEST:CAN CAUSE STOM &/OR INTESTINAL IRRIT (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NAUSEA, VOMIT & DIARRHEA.
CHRONIC:REPORTS HAVE ASSOC RPTD & PRLNGD OCCUP OVEREXP TO SOLVS
W/PERM BRAIN & NERVOUS SYS DMG. PRLNGD/RPTD BRTHG OF SPRAY MIST
&/OR SANDING DUST OVER A PERIOD OF YR S MAY CAUSE DUST DISEASE OF
LUNGS. NOTICE:INTENTIONAL MISUSE BY DELIB CONC & INHALING CONTENTS
MAY BE HARMFUL OR FATAL.
Medical Cond Aggravated by Exposure:NONE WHEN USED I/A/W SAFE HANDLING
AND USE INFORMATION. DO NOT USE IF YOU HAVE LUNG OR BREATHING
PROBLEMS OR PRIOR REACTION TO ISOCYANATES.

First Aid

First Aid:INHAL:IF DFCLTY BRTHG, REMOVE TO FRESH AIR. IF CONTINUED
DFCLTY, CALL MD IMMED. IF BRTHG STOPS, RESTORE USING APPRVD CPR &
CALL MD IMMED. EYE:FLUSH IMMED W/LG AMTS OF WATER FOR AT LEAST 15
MIN. GET MD . SKIN:WASH AFFECTED AREAS W/SOAP & WATER. REMOVE
SOILED CLTHG. GET MD IF IRRIT PERSISTS. INGEST:CALL MD IMMED. DO
NOT INDUCE VOMIT. ASPIR OF VOMIT CAN CAUSE CHEM PNEUM WHICH CAN BE
FATAL.

Fire Fighting

Flash Point Method:SCC
Flash Point:80.0F,26.7C
Lower Limits:1%
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, FOAM OR OTHER
NFPA APPROVED METHOD FOR TREATING A CLASS B FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT
EQUIP.WATER SPRAY MAY BE INEFTIVE. IF USED, FOG NOZZ PREF. IF EXPSD
TO FIRE/EXTREME HEAT, WATER SHOULD (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLOSED. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & FLAME. VAPORS MAY CAUSE FLASH FIRE; MAY
IGNITE EXPLO; MAY SPREAD LONG DISTANCES &(SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES,HOT SURFS
& ELEC, STATIC/FRICTIONAL SPARKS). PVNT BRTHG OF VAPS. VENT AREA.
BEFORE TRYING CLEAN-UP,REFER TO HAZ CAUTION INFO. CONTAIN SPILLED
MATL & REMOVE W/INERT ABSORB & NON-SPARKING TOOLS. STORE IN (ING
5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID HEAT/SPARKS/FLAMES. DO NOT
SMOKE. DO NOT STORE >120F/NEAR FIRE/OPEN FLAME. STORE LG QTYS IN
BLDGS TO COMPLY W/OSHA 1910.106. DO NOT GET ON SKIN.
Other Precautions:EXTING ALL PILOT LIGHTS & TURN OFF ALL SOURCES OF
IGNIT INCLDG HEATERS, FANS & OTHER NON-EXPLO-PROOF ELEC EQUIP,
DURING USE & UNTIL ALL VAPS GONE. VAPS MAY IGNITE EXPLO. VAPS MAY
SPREAD LONG DISTANCES & BEYOND CLOSED DOORS. PREVENT (ING 6)

Exposure Controls

Respiratory Protection:WEAR PROPERLY FITTED NIOSH/MSHA APPRVD AIRLINE
RESP DURING & AFTER APPLICATION UNLESS MONITORING DEMONSTRATES VAP,
MIST & PARTICULATE LEVELS BELOW APPLIC LIM. USE NIOSH/MSHA APPRVD
RESP WHEN FLAME CUT TING/WELDING/BRAZING & SANDING (ING 9)
Ventilation:GEN DILUTION/LOCAL EXHST VENT IN VOLUME & PATTERN TO KEEP
AIR CONTAMINANT CONC BELOW CURRENT APPLIC SAFETY & (ING 10)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SOLVENT IMPERMEABLE CLOTHING & BOOTS.
Work Hygienic Practices:REMOVE & WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC:BE USED TO COOL CLOSED CNTNRS & PVNT PRESS BUILDUP/POSS
AUTO-IGNIT. EXPLO HAZ: BEYOND CLOSED DOORS. DUE TO PRESS BUILD-UP,
CLOSED CNTNRS EXPOSED TO EXTREME HEAT MAY EXPLODE. NEVER USE
WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMPTY) AS PROD/ITS
RESIDUE MAY IGNITE. DURING EMER COND OVEREXPOS TO (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>252F,>122C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.042
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:30

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CO, CO*2, NO*X.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL
REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.